Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Brand: WXKF
Warranty: 1 Year
Type: Gas Density Relay
Customized Support: Oem
Brand Name: WXKF
Model Number: KMJ100
Product Name: KMJ SF6 Gas Density Relay
Nominal Diameter: 64mm
Connection: General type with bottom connection
Measuring Range: -0.1~ 0.1MPa ; -0.1~0.15Mpa; 0 ~ 2.0bar
Precision Class: 20℃ : class 1.5;-30℃~+60℃: class 2.5
Working Environment: -30℃~60℃, relative humidity:≤95% PH
Lmpact Class: 30g(general); 50g (shockproof)
Warranty Period: 3 Years
Support Customization: Oem, Odm, Obm
Place Of Origin: Jiangsu, China
Certification: ISO, ce
Packaging: carton
Productivity: 300 millions
Transportation: Ocean,Land,Air,Express,Express
Place of Origin: China
Certificate: ISO9001
HS Code: 9026209090
Port: Shanghai Port
Payment Type: L/C,T/T,D/P,D/A,Paypal,Money Gram,Western Union,D/A
Incoterm: FOB,CFR,CIF,EXW,FAS,FCA,CPT,CIP,DEQ,DDP,DDU,Express Delivery,DAF,DES
SF6 Gas Density Monitor Working Mechanism:
Density Relay is composed of the density detection system including pressure sensing elements a drive mechanism, temperature compensation elements, an indication unit and an electric contact unit.
it uses the pressure measuring principle with temperature compensation to measure the pressure of the SF6 gas under certain density in the sealed vessel for field test and control through a density detection system thus achieves the goal of Gas Density monitoring.
In a sealed vessel.the pressure of SF6 gas under certain temperature(20C)can be seen as the gas density under this temperature (20C) We take the SF6 gas pressure value under 20C as the representative value of its density and also as the scale value.When the ambient temperature chandes. the temperature compensation elements will compensate for the aas pressure change caused by the temperature change.Therefore,as long as the SF6 gas density remains unchanged,the indication value of the density meter will keep the same.
When SF6 gas is filled into the sealed vessel or the gas changes,pressure sensing elements wil make displacement which is converted into the indication value through the drive mechanism.When the ambient temperature change induces the indication value change,the temperature compensation elements will make compensation and correction.
In the electric contact unit.when SF6 gas density lowers to certain preset valuecorrect and reliable alarm or lock control signals will be sent out to ensure normal and safe operation of the electric equipment.
what is the main technical data of SF6 Gas Density Monitor ?
1.Working environment: | -30℃~60℃, relative humidity:≤95% PH |
2.lngress Protection | IP 65 |
3.Vibration resistance in working environment | class 1 (general); class 2 (shockproof) |
4.lmpact class | 30g(general); 50g (shockproof) |
5.Leakage ratio | ≤1x10-9 Pa.m3/s (helium leak detection) |
6.Contact type | magnetic aid electric contact switch 80%silver, 20%nickel, 10µm gold plated |
7.Electric parameters of the contact | AC: 30VA 380V 1.0A DC: 30W 220V 1.0A |
8.lnsulation performance insulating resistance | 100MΩ (500VDC) |
9.Power-frequency withstand voltage | 2000V 45/60HZ.1 min |
SF6 Gas Density Monitor Features
1. Electric contact switch design realizes accurate and reliable SF6 gas monitoring functions.
2. With temperature compensation, the compensation performance is stable and the detection precision is high.
3. On-site display values and output contact signals are not affected by external conditions including the altitude and ambient temperature change.
4. Core elements are made of imported materials with high precision.
5. Good shockproof performance.
6. There are three contact groups at most, which can realize several options including overpressure alarm, double alarm or double lock and make the monitoring safer and more reliable.
7.Gas fill, micro-water test and calibration can be implemented without removal of the SF6 gas density relay, making it easy for on-site staff to conduct micro-water test and gas supplementand avoiding the seal face and seal ring damage arising from removal.
8.304 stainless steel is adopted for the sealed case, which prevents both moisture and corrosion.
Q1. What is your terms of packing?
A: Generally, we pack our goods in neutral white boxes and brown cartons. If you have legally registered patent, we can pack the goods in your branded boxes after getting your authorization letters.
Q2. What is your terms of delivery?
A: EXW, FOB, CFR, CIF, DDU.
Q3. How about your delivery time?
A: Generally, it will take 30 to 60 days after receiving your advance payment. The specific delivery time depends on the items and the quantity of your order.
Q4. Can you produce according to the samples?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
Q5. What is your sample policy?
A: We can supply the sample if we have ready parts in stock, but the customers have to pay the sample cost and the courier cost.
Q6. Do you test all your SF6 gas density monitor before delivery?
A: Yes, we have 100% test before delivery
Q7: How do you make our business long-term and good relationship?
A:1. We keep good quality and competitive price to ensure our customers benefit ;
2. We respect every customer as our friend and we sincerely do business and make friends with them, no matter where they come from.
Product Categories : Gas Density Monitor > SF6 Gas Density Monitor
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.